How many luminaires to use

Prepared from materials of Euroformat.

The number of luminaires comes from the illuminance required for the room. First calculate the total power, then divide it by the power of one luminaire.

Norm, lm/m² × area, m² × height factor ÷ efficacy = power, W

The lumen (lm) is a unit of luminous flux, not a fixed coefficient. More lumens means more light from the LEDs. In the formula for LED luminaires the efficacy is 90.

The norms in the table are the lower illuminance for the room. The source relates them to SNiP.

Room

Norm, lm/m²

Living room, kitchen

300

Children's room

400

Bathroom, toilet, corridor

200

Study, library

500

Wardrobe

100

Sauna, pool

200

Office with computers

500

Classroom

800

Conference room

450

Entrance hall

200

Utility room, storeroom

100

The height factor raises the power when the ceiling is higher than usual.

Ceiling height

Factor

up to 2.5 m

1

up to 3 m

1.2

up to 3.5 m

1.5

up to 4.5 m

2

Example

A children's room of 20 m² with a ceiling height of 2.7 m. The children's-room norm is 400 lm/m², and the factor for a height up to 3 m is 1.2.

400 × 20 × 1.2 ÷ 90 = 106.7 W

The notebook rounds the same example to 106 W. Then divide the total power by the power of one luminaire and round up, so the result does not fall below the norm:

  • 106.7 ÷ 8 ≈ 13.3 → 14 luminaires of 8 W;

  • 106.7 ÷ 12 ≈ 8.9 → 9 luminaires of 12 W;

  • 106.7 ÷ 20 ≈ 5.3 → 6 luminaires of 20 W.

The notebook lists 13, 9, and 5 for this example. Nine luminaires of 12 W give 108 W and cover the calculation. Five of 20 W give 100 W, which is below 106.7 W, so the formula needs a sixth.

Light color

The scale below runs from warm light on the left to cool light on the right. It does not change the luminaire count.

The strip power supply and the controller current are separate: power supply and controller or dimmer.