Basic measurement rules

Prepared from materials of Euroformat.

Start at corner A and measure so that every ceiling vertex sits in a triangle with known sides. Enter those dimensions in construction through side lengths and diagonals.

Corner A and walk direction

Corner A is to the left of the entrance. Walk strictly clockwise: A → B → C → D and on around the contour.

On the diagram the entrance is marked with two ticks on the side next to corner A.

Closed triangles

Split a polygonal or curved ceiling into closed triangles with diagonals. Every vertex needs a diagonal that closes a triangle with sides you already know. Without that, the drawing in the program is not determined.

If you cannot shoot a diagonal, use arcs and chords or add an extra point as described below.

Shelf on a level change

A shelf is the strip of material for a level change. Add it to the contour and tie the step to the upper and lower outlines with diagonals.

In the program, set the step height with the Level form.

Extra point

If you cannot shoot a diagonal from the existing corners, place an extra point on a reachable side and close the triangles from there.

On the diagram this is point L on side MK. Diagonals from L and from corner M reach vertices that would otherwise have no triangle.

In the program, add that vertex with the Point form.